Rated Power 500W |
Input | 90V-264VAC(47Hz-63Hz) 8A Max | |||
Output | Load Range | Voltage | Ripple & Noise | ||
Min | Max | ||||
+5V | 0.5A | 20A | ±5% | ≤50mV | |
+12V | 1A | 35A | ±5% | ≤120mV | |
+5VSB | 0.1A | 2A | ±5% | ≤50mV | |
+3.3V | 0.8A | 20A | ±5% | ≤50mV | |
-12V | 0A | 0.5A | ±10% | ≤120mV | |
Not exceeding 115W if combines +3.3V and +5V together | |||||
Standby Power Consumption | ≤3W | ||||
Protective Function | Overvoltage protection, over power protection, short circuit protection, | ||||
Working Environment | Air Temperature:0℃~40℃,Relative Humidity:5%~85% without condensation | ||||
Storage Environment | Air Temperature:-40℃~55℃,Relative Humidity:5%~95% | ||||
EMI | Conform EN55022 Class B GB9254 Class B | ||||
Earth Leakage Current | ≤3.5mA(264VAC/50Hz) | ||||
MTBF Value | ≥100K hours.MIL-HDBK-217F(25℃) | ||||
Cooling Method | Forced cooling and fan cooling method | ||||
Package Method | 8PCS/Per Case | ||||
Typical Dimensions(mm) | 240(L)×100(W)×70(H) | ||||
Design Standards | Conform SSI EPS 2.1 server power supply standards 2U standard | ||||
Application | ATM, self-service terminals, etc. |