Rated Power 250W |
Input | 90V-264VAC(47Hz-63Hz) 5A Max | |||
Output | Load Range | Voltage | Ripple & Noise | ||
Min | Max | ||||
+5V | 0.3A | 12A | ±5% | ≤50mV | |
+12V | 1A | 18A | ±5% | ≤120mV | |
+5VSB | 0A | 2A | ±5% | ≤50mV | |
+3.3V | 0.5A | 16A | ±5% | ≤50mV | |
-12V | 0A | 0.5A | ±5% | ≤120mV | |
Not exceeding 240W if combines +3.3V,5V and +12V together | |||||
Standby Power Consumption | ≤3W | ||||
Protective Function | Overvoltage protection, over power protection,short circuit protection, | ||||
Working Environment | Air Temperature:0~50℃,Relative Humidity:5%~95% without condensation | ||||
Storage Environment | Air Temperature:-40~70℃,Relative Humidity:5%~100% | ||||
EMI | Conform EN55022 Class B GB9254 Class B | ||||
Earth Leakage Current | ≤3.5mA(264VAC/50Hz) | ||||
MTBF Value | ≥100K hours.MIL-HDBK-217F(25℃) | ||||
Cooling Method | Forced cooling and dual ball fan cooling method | ||||
Package Method | 10PCS/Per Case | ||||
Typical Dimensions(mm) | 190(L)×100(W)×40(H) | ||||
Design Standards | Conform SSI 1U 2.93Industrial server power supply standards | ||||
Application | Network Server, IPC, etc |