| Model HK450-91PP |
Input | 90-265VAC(47Hz-63Hz) 3A Max | |||
| Output | Load Range | Voltage | Ripple & Noise | ||
| Min | Max | ||||
| +5V | 0.1A | 15A | ±5% | ≤50mV | |
| +12V | 0.1A | 28A | ±5% | ≤120mV | |
| +5VSB | 0A | 2A | ±5% | ≤50mV | |
| +3.3V | 0.1A | 15A | ±5% | ≤50mV | |
| -12V | 0A | 0.3A | ±10% | ≤120mV | |
| Not exceeding 120W if combines +3.3V and 5V together | |||||
| Standby Power Consumption | ≤3W | ||||
| Protective Function | Over voltage protection, over power protection, over temperature protection, short circuit protection | ||||
| Working Environment | Air Temperature:0~50℃,Relative Humidity:5%~85% without condensation | ||||
| Storage Environment | Air Temperature:-40~70℃,Relative Humidity:5%~95% | ||||
| EMI | Conform EN55022 Class B, GB9254 Class B | ||||
| Earth Leakage Current | ≤3.5mA(264VAC/50Hz) | ||||
| MTBF Value | ≥50K hours.Bellcore-TR-332(25℃) | ||||
| Cooling Method | Forced cooling and fan cooling method | ||||
| Package Method | 20PCS/Per Case | ||||
| Typical Dimensions(mm) | 150(L)×80(W)×40(H) | ||||
| Design Standards | Comply with Intel Flex 12V 1.0 Standard | ||||
| Application | Network Server, IPC , etc. | ||||